# I2C Modbus RS232 (IS4310)

The IS4310-232M4 is a ready-to-operate module integrating the Modbus RTU Slave chip IS4310 with an RS232 transceiver

- **Seller:** [INACKS](https://lectronz.com/stores/inacks), Terrassa, Barcelona, Spain
- **Price:** €7.00 (EUR, before shipping and taxes)
- **Availability:** Retired, no longer sold
- **Categories:** Components, I2C, Home automation
- **Product page:** https://lectronz.com/products/i2c-modbus-rs232-is4310

## Links

- [Documentation](https://inacks.gitbook.io/is4310-wiki)
- [Code](https://github.com/inacks/IS4310-Modbus-Arduino-Sensor-Example1033)

## Images

![I2C Modbus RS232 (IS4310)](https://lectronz-images.b-cdn.net/lectronz/active_storage/representations/proxy/eyJfcmFpbHMiOnsiZGF0YSI6MzA4ODYsInB1ciI6ImJsb2JfaWQifX0=--b1d31224acc051ca06940ac02a99976c211f6689/eyJfcmFpbHMiOnsiZGF0YSI6eyJmb3JtYXQiOiJqcGciLCJyZXNpemVfdG9fbGltaXQiOls5NjAsNjQwXSwic2F2ZXIiOnsic3RyaXAiOnRydWV9fSwicHVyIjoidmFyaWF0aW9uIn19--970c165836a83091725a1a0fd4f37ce9408da1bf/IS4310-232M4%20(1).jpg)
![I2C Modbus RS232 (IS4310)](https://lectronz-images.b-cdn.net/lectronz/active_storage/representations/proxy/eyJfcmFpbHMiOnsiZGF0YSI6MzA4OTAsInB1ciI6ImJsb2JfaWQifX0=--1b5106e7b45b371428167100540eb9dff459e224/eyJfcmFpbHMiOnsiZGF0YSI6eyJmb3JtYXQiOiJqcGciLCJyZXNpemVfdG9fbGltaXQiOls5NjAsNjQwXSwic2F2ZXIiOnsic3RyaXAiOnRydWV9fSwicHVyIjoidmFyaWF0aW9uIn19--970c165836a83091725a1a0fd4f37ce9408da1bf/IS4310-232M4%20(2).jpg)
![I2C Modbus RS232 (IS4310)](https://lectronz-images.b-cdn.net/lectronz/active_storage/representations/proxy/eyJfcmFpbHMiOnsiZGF0YSI6MzA4OTQsInB1ciI6ImJsb2JfaWQifX0=--78c252ecfd317fd51f14f29aad43ee40da38611d/eyJfcmFpbHMiOnsiZGF0YSI6eyJmb3JtYXQiOiJqcGciLCJyZXNpemVfdG9fbGltaXQiOls5NjAsNjQwXSwic2F2ZXIiOnsic3RyaXAiOnRydWV9fSwicHVyIjoidmFyaWF0aW9uIn19--970c165836a83091725a1a0fd4f37ce9408da1bf/IS4310-232M4%20(3).jpg)
![I2C Modbus RS232 (IS4310)](https://lectronz-images.b-cdn.net/lectronz/active_storage/representations/proxy/eyJfcmFpbHMiOnsiZGF0YSI6MzA4OTgsInB1ciI6ImJsb2JfaWQifX0=--085864c9ee1bbd93adc9dbb20606fc3942300671/eyJfcmFpbHMiOnsiZGF0YSI6eyJmb3JtYXQiOiJqcGciLCJyZXNpemVfdG9fbGltaXQiOls5NjAsNjQwXSwic2F2ZXIiOnsic3RyaXAiOnRydWV9fSwicHVyIjoidmFyaWF0aW9uIn19--970c165836a83091725a1a0fd4f37ce9408da1bf/IS4310-232M4%20(4).jpg)
![I2C Modbus RS232 (IS4310)](https://lectronz-images.b-cdn.net/lectronz/active_storage/representations/proxy/eyJfcmFpbHMiOnsiZGF0YSI6MzE2OTEsInB1ciI6ImJsb2JfaWQifX0=--e1a85540a72ec484cb9778f7de3513828725aa24/eyJfcmFpbHMiOnsiZGF0YSI6eyJmb3JtYXQiOiJwbmciLCJyZXNpemVfdG9fbGltaXQiOls5NjAsNjQwXSwic2F2ZXIiOnsic3RyaXAiOnRydWV9fSwicHVyIjoidmFyaWF0aW9uIn19--605f1da017bcbb03ce31845cd0e81d97e3b3c574/IS4310%20Flyer.png)
![I2C Modbus RS232 (IS4310)](https://lectronz-images.b-cdn.net/lectronz/active_storage/representations/proxy/eyJfcmFpbHMiOnsiZGF0YSI6MzE2NzksInB1ciI6ImJsb2JfaWQifX0=--edbf55657568225748008a3a5ab008b61de42e49/eyJfcmFpbHMiOnsiZGF0YSI6eyJmb3JtYXQiOiJwbmciLCJyZXNpemVfdG9fbGltaXQiOls5NjAsNjQwXSwic2F2ZXIiOnsic3RyaXAiOnRydWV9fSwicHVyIjoidmFyaWF0aW9uIn19--605f1da017bcbb03ce31845cd0e81d97e3b3c574/IS4310%20Diagram.png)
![I2C Modbus RS232 (IS4310)](https://lectronz-images.b-cdn.net/lectronz/active_storage/representations/proxy/eyJfcmFpbHMiOnsiZGF0YSI6MzE2ODMsInB1ciI6ImJsb2JfaWQifX0=--254d7054c932ae47f3fee33223e223ad4969cb8e/eyJfcmFpbHMiOnsiZGF0YSI6eyJmb3JtYXQiOiJqcGciLCJyZXNpemVfdG9fbGltaXQiOls5NjAsNjQwXSwic2F2ZXIiOnsic3RyaXAiOnRydWV9fSwicHVyIjoidmFyaWF0aW9uIn19--970c165836a83091725a1a0fd4f37ce9408da1bf/IS4310%20Memory%20Map%20(Tin).jpg)
![I2C Modbus RS232 (IS4310)](https://lectronz-images.b-cdn.net/lectronz/active_storage/representations/proxy/eyJfcmFpbHMiOnsiZGF0YSI6MzE2ODcsInB1ciI6ImJsb2JfaWQifX0=--f844949d8737d0238ffc7ee6fa28436fe4f0d50f/eyJfcmFpbHMiOnsiZGF0YSI6eyJmb3JtYXQiOiJQTkciLCJyZXNpemVfdG9fbGltaXQiOls5NjAsNjQwXSwic2F2ZXIiOnsic3RyaXAiOnRydWV9fSwicHVyIjoidmFyaWF0aW9uIn19--4157f0fb908a7cf53a9fb69e24400c01800a5257/IS4310%20Memory%20Map.PNG)
![I2C Modbus RS232 (IS4310)](https://lectronz-images.b-cdn.net/lectronz/active_storage/representations/proxy/eyJfcmFpbHMiOnsiZGF0YSI6MzE2OTUsInB1ciI6ImJsb2JfaWQifX0=--22c67aa4825b64b656942306e2f24309bbb69278/eyJfcmFpbHMiOnsiZGF0YSI6eyJmb3JtYXQiOiJKUEciLCJyZXNpemVfdG9fbGltaXQiOls5NjAsNjQwXSwic2F2ZXIiOnsic3RyaXAiOnRydWV9fSwicHVyIjoidmFyaWF0aW9uIn19--a1419a086f227676aca33a49760ac51e58b523e3/IS4310-232M4%20Datasheet%20Cover.JPG)
![I2C Modbus RS232 (IS4310)](https://lectronz-images.b-cdn.net/lectronz/active_storage/representations/proxy/eyJfcmFpbHMiOnsiZGF0YSI6MzE2OTksInB1ciI6ImJsb2JfaWQifX0=--2e815fbc73a83fe4e440f3766963e21bddb88202/eyJfcmFpbHMiOnsiZGF0YSI6eyJmb3JtYXQiOiJKUEciLCJyZXNpemVfdG9fbGltaXQiOls5NjAsNjQwXSwic2F2ZXIiOnsic3RyaXAiOnRydWV9fSwicHVyIjoidmFyaWF0aW9uIn19--a1419a086f227676aca33a49760ac51e58b523e3/IS4310-232M4%20Product%20Catalog.JPG)
![I2C Modbus RS232 (IS4310)](https://lectronz-images.b-cdn.net/lectronz/active_storage/representations/proxy/eyJfcmFpbHMiOnsiZGF0YSI6MzE3MDMsInB1ciI6ImJsb2JfaWQifX0=--ebb1a76e2d9fb4e971886f92446c172941cf724a/eyJfcmFpbHMiOnsiZGF0YSI6eyJmb3JtYXQiOiJKUEciLCJyZXNpemVfdG9fbGltaXQiOls5NjAsNjQwXSwic2F2ZXIiOnsic3RyaXAiOnRydWV9fSwicHVyIjoidmFyaWF0aW9uIn19--a1419a086f227676aca33a49760ac51e58b523e3/IS4310-232M4%20Schematic.JPG)

## Description

The IS4310-232M4 is a ready-to-operate module integrating the Modbus RTU Slave chip IS4310 with an RS232 transceiver. This solution reduces to the minimum expression the design effort of integrating a Modbus RTU Slave with an RS232 electrical interface.

The module can be directly soldered to your PCB with its castellated holes, or you can solder a pin header and use it as a module.


## Shipping policy

We ship all products from Barcelona via UPS within 1–2 business days. A tracking number is provided. Transit time is typically less than one week worldwide (excluding handling time).
